Showing results: 61 - 75 of 95 items found.
-
LineTroll R400D -
Nortroll
LineTroll R400D Fault Indicator indicates earth- and short-circuit faults and can distinguish between permanent and transient faults. The indicator has two sensors and use both the electrical field and the magnetical field to detect faults on all three phases.
-
DC Trace -
Scope T&M Pvt, Ltd.
SCOPE introduces DC Trace, the most advanced and user friendly DC Earth (Ground) Fault Locator. This portable instrument consisting of Signal Generator & Signal Receiver (DC TraceR) uses latest digital signal processing technology. It’s ability to detect earth faults in live DC system quickly & accurately in online condition greatly relieves the substation maintenance engineers from nightmare of earth leakages & it’s detection.
-
CableTroll -
Nortroll
They are installed on Ring Main Units in distribution substations. They are used to detect short circuit and earth faults, and can be installed on most types of cable terminations. Some units will give separate indications for short circuit and earth faults, locally by flashing diodes and remotely through separate relay contacts or additional ComTroll communications modules.
-
Mors Smitt Group
The main earth fault protection relays in distributions systems, power stations & large manufacturing / processing plants can fail to detect a high impedance break down to earth causing hazard to human life & potential damage to plant & equipment. In these & other situations demanding extra sensitive earth fault protection, using solid state techniques, can be applied to detect earth currents down to 0.5% of the CT nominal current.The relay is tuned to reject 3rd & higher harmonic frequencies to avoid problems under quiescent conditions. An adjustable time delay is built in to provide stability during switching & other transient disturbances & to allow adequate grading with other protection systems at high fault current levels.
-
Chauvin Arnoux Metrix
Are designed for measuring leakage current diverted towards the earth. It enables the fault to be located or anticipated without disconnecting the equipment linked. It is specially designed to detect low fault currentson power circuits.
-
KV Hipot Power Test Equipment Co.,Ltd
resistance tester is used to measure the resistance of the earth is called Earth Resistance Tester. All the equipment of the system is grounded through the earth electrode. Unhindered earthing protects electrical equipment and personnel from the fault current.
-
Accumetrics Associates, Inc.
The Earth Fault Resistance Monitor (EFREM) and the Rotor Health Monitor (RHM) provide wireless rotor ground fault and temperature monitoring for generators and motors. The systems replace older slip ring contact ground fault detectors on any synchronous generator or motor.
-
Signals & Systems India Private Limited
The Display used to monitor the 20Hz and 50Hz current passing through NGT transformer. This could help to monitor the stator earth fault and could record the current every minute. The current shall be displayed in milliamps for both 20Hz and 50Hz. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. The current can be measured using clamp-on CT which would be clamped between load resistor and NGT. It gives an indication of the current values are lower or higher than the set threshold.
-
Cambridge Instruments & Engineering Co.
“CIE” Relay Test Set is ideal for Testing Protective relay, over current relay, earth fault relay by secondary injection method with help of digital timer.
-
DCZCT-45NK -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement*DC leakage current measurement*Least affection from the magnetization of core and temperature fluctuation*Convenient +24V single polarity power supply
-
DCZCT-60NK -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement*DC leakage current measurement*Least affection from the magnetization of core and temperature fluctuation*Convenient +24V single polarity power supply
-
K-3837 -
Kongter Test & Measurement Co., Limited
Kongter’s K-3837 Ground Fault Locator is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems with earth fault. It will save you from long time unnecessary troubleshooting and helps to increase the stability of your electrical equipments. It is widely used in various DC systems including power utilities, locomotive, telecom and etc.
-
Megger Group Ltd.
Megger loop testers offer both traditional measuring techniques and state of the art “non-RCD Tripping” technology. Use these products to determine the prospective earth fault current, which is the maximum current able to flow in a phase-earth fault in an installation, and also to indicate the prospective short circuit current which is the maximum current able to flow in the event of a phase-neutral fault.
-
TAURUS PRECIOHM ET -
Taurus Powertronics Systems
The TAURUS PRECIOHM ET is one of the specially designed products by TAURUS to measure earth resistivity and earth resistance in a power station. These tests are performed based on 4 point (Wenner) and 3 point (fall of potential) methods respectively. All electrical equipment in the substation and power stations are electrically connected to station earth mat with earth electrodes. The earth electrode ensures that in the event over voltage on the system due to system fault or lighting discharges etc., the parts of the equipment which are normally ”dead” as far as voltages are concerned; do not attain dangerously high potentials. An earth electrode will only be effective so long it has a low resistance to the earth and can carry large currents without deteriorating. Thus the resistance of earth electrode should be low to give good protection and it must be continuously measured and monitored in all the substations and power stations.
-
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of ground fault locator from basic to advanced model to fast detect, trace and pinpoint virtual grounding faults in DC systems when systems are LIVE (working online). Without injecting any signal to the DC system, they are safe to your existing system. With Kongter’s unique technique for signal tracing, these ground fault locators are much faster and more effective to find the earth fault in the field than its peers.